1 relay will close the electrical circuit between the screw terminals no. If at this moment we enter the “M3” into the MDI line and we press ENTER the no. Pins no.1 and 2 of the relays were placed on 12, 13, and 25 screw terminals of the green block connector described as „STEP & DIGITAL OUTPUTS” In this case you should skip any configuration steps for „Output#2” in further stages.ī) Next we assign Port and Pin for virtual outputs: „Output#1” and „Output#2”.Īs you can see in the picture above I chose 4 and 5 „Pin”, my choice wasn’t accidental – namely, these “Pins” in the CSMIO/IP-M controller are responsible for relays no.1 and no.2 (Note: for relays work the acceptable parameters are 100mA and 30V DC). For the spindles which don’t have backward revs we can choose „Output#1” twice. In order to fully control the VFD through the Mach3, both Mach3 and plugin must be configured in two stages: Stage 1 ) CSMIO/IP-M relay outputs configurationĪ) We start the configuration with choosing the „M3” and „M4” commands of virtual outputs: „Output#” ![]() The article is about CSMIO/IP-M but the configuration applies to all CSMIO/IP controllers. Correct configuration of Mach3 software and plugin to control the VFD
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |